Skip to content

Command Line Reference

To launch VIOSO from the command line, you must first locate its executable file (.exe). This will depend on the path you chose during installation. The standard installation path is C:\Program Files\VIOSO6\

The executables are located in these folders:

  • VIOSO 7: C:\Program Files\VIOSO7\SPCalibrator64.exe
  • VIOSO 6: C:\Program Files\VIOSO6\SPCalibrator64.exe
  • VIOSO 6 Blackbox (for SIM applications):
    Standard build: C:\Program Files\VIOSO6\Blackbox64.exe
    Build with Datapath Vision Support: C:\Program Files\VIOSO6\BlackboxVRGB64.exe

You can also start the application from the Windows Start Menu: All Programs / VIOSO6

ParameterDescriptionNote
/0start application with blocked UI always (pure client mode)
/astarts a recalibration behaviour on application startupFree mode
/Astarts a recalibration behaviour on application startup and closes when the calibration is done Free mode
/C:"path"path of the (.ini) file directory to useremoved in VIOSO 6
/Eexports using using automation script after load and recalibration, if specified Free mode
/F:"profile"prefered GUI Profile (if available) accepted profiles: ”file player”, ”Standard”, “first init”
/I:"ip"initializes a network adapter (IP address) to use
/Hstarts the application in scripting host mode, able to perform complex automatic behaviour, defined via script files
/H:"file"starts the application in scripting host mode and loads a scripting file (.ini) on startup, requires full path Free mode
/L:"file"loads a calibration file on startup, requires full path. e.g.: /L:"D:\Calibration\calib_Final.sps" Free mode
/Lang:ndefines the default language of the application (n: Language code, ex: 1033: English US; 1031 German Germany)
/Mstarts application GUI minimized
/O:"path"path => name of the project path to use at startupnew in VIOSO 6
Project Mode
/Q:"step"can be used to define the project step that should be processed at startup
available values: “Design”, “Calibrate”, “Edit”, “Edit MRD”, “Export”,
“Recalibrate”, “Activate”, “Deactivate” , “Configure”
in additional, parameters can be defined with: /Q: "step;param=value; …"
accepted parameters:
CloseAfter : the application should be closed after performing the step
parameter values: yes, no
new in VIOSO 6
Project Mode
/Rstarts playout automatically on application startup
/S:"path"path of the data exchange directory to use
/VVerbose mode (gives detailed information on errors)
/X:"name"Name of the memory file in case of IPC using
/Ztry to use the generic 0 display license

This command starts VR&SIM with the following operations:

Terminal window
C:\Program Files\VIOSO6\SPCalibrator64.exe /L:"final.sps" /S:"D:\VIOSO\Calib" /I:"192.168.0.1" /M
  • loads “final.sps” from the standard data path
  • uses D:\VIOSO\Calib as standard data path
  • initializes network interfaces of application on the adapter 192.168.0.1
  • starts the application minimized